Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Braz. dent. sci ; 25(1): 1-14, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1361900

ABSTRACT

Objetivo: O objetivo do presente estudo foi avaliar a eficácia da adição de nanopartículas de óxido de zircônio (ZrO2), óxido de titânio (TiO2) e óxido de sílica (SiO2) a um material de revestimento macio curado a frio na adesão de Candida albicans (CA). Material e Método: Cinquenta e quatro pacientes foram selecionados e divididos em três grupos de acordo com a modificação do revestimento com nanopartículas de ZrO2, TiO2 e SiO2 (18 cada). Cada paciente recebeu prótese total maxilar com três cavidades, as cavidades foram revestidas com forro macio curado a frio modificado com diferentes concentrações (0%, 3% e 7%) de nanopartículas de óxido metálico. Nos dias 14 e 28, as trocas foram retiradas do local de realinhamento e imediatamente cultivadas para avaliação fúngica. O número de colônias foi contado, os dados coletados e explorados para normalidade usando o teste de Shapiro-Wilk e a transformação logarítmica da contagem de CA foi realizada. ANOVA para medidas repetidas e de uma via (one-way) foram usados, seguidos por teste de Tukey (HSD). O teste t independente foi usado para comparar as contagens de CA em diferentes períodos. Resultados: A adesão do CA foi significativamente diminuída pela adição de nanopartículas de ZrO2, TiO2 e SiO2 em comparação com o grupo controle, também a cobertura antifúngica aumentou com o aumento da concentração de nanopartículas (p <0,005). A maior contagem de CA foi identificada no grupo SiO2 seguido por ZrO2, enquanto TiO2apresentou a menor contagem de CA (p <0,001). Conclusão: Adição de diferentes nanopartículas; ZrO2, TiO2 e SiO2para revestimento macio curado a frio é um método eficaz para reduzir a adesão de CA (AU)


Objective: The aim of the current study was to evaluate the efficacy of addition of zirconium oxide (ZrO2), titanium oxide (TiO2), and silica oxide (SiO2) nanoparticles to cold-cured soft liner on adhesion of Candida albicans (CA). Material and Methods: Fifty-four patients had been selected and divided into three groups according to the modification of soft liner with ZrO2, TiO2, and SiO2 nanoparticles (18 each of). Each patient received maxillary complete denture having three cavities, the cavities were lined using cold cured soft liner modified with different concentration (0%, 3%, and 7%) of metal oxide nanoparticles. On days 14 and 28, swaps were taken out from relining site and immediately cultured for fungal evaluation. The number of colonies were counted, data collected and explored for normality using Shapiro-Wilk test, logarithmic transformation of CA count was performed. Repeated and one-way ANOVA were used followed by Tukey HSD. Independent-t test used to compare between CA counts at different periods. Results: The CA adhesion was significantly decreased by the addition of ZrO2, TiO2 and SiO2 nanoparticles in comparison with control group, also the antifungal coverage increased with nanoparticles concentration increased (P<0.005). The highest CA count was identified in group SiO2 followed by ZrO2, while TiO2 showed the lowest CA count (P <0.001). Conclusion: Addition of different nanoparticles; ZrO2, TiO2 and SiO2 to cold-cured soft liner is an effective method for reducing CA adhesion. (AU)


Subject(s)
Humans , Candida albicans , Denture Liners , Nanoparticles , Antifungal Agents
2.
Braz. dent. sci ; 24(2): 1-8, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1177389

ABSTRACT

Objetive: This study was to compare the effectiveness of arthrocentesis versus the insertion of anterior repositioning splint (ARS) in improving the mandibular range of motion (MRM) for patients with the temporomandibular joint (TMJ) anterior disc displacement with reduction (ADDwR). Methods: 36 patients diagnosed as ADDwR were recruited and divided randomly into two groups. The first group (G1) was treated by arthrocentesis, and the second (G2) was treated using ARS. All patients were reexamined after six months. Results: Except that for protrusive movement, there were significant differences between the two groups for the percentage changes of the MRM as measured by the amount of pain free opening, unassisted opening, maximum assisted opening, right lateral and left lateral movements (p < 0.05). Conclusion: Within the context of the current study, the non-invasive, lower cost ARS, provided better results in improving the MRM when managing ADDwR cases. (AU)


Objetivo: O presente estudo comparou a eficácia da Artrocentese em relação à inserção da Placa Reposicionadora Anterior (PRA) na melhoria da Amplitude de Movimento Mandibular (AMM) para pacientes que apresentam Deslocamento de Disco Anterior com Redução (DDAcR) da Articulação Temporomandibular (ATM). Método: 36 pacientes diagnosticados como DDAcR foram recrutados e divididos aleatoriamente em dois grupos. O primeiro grupo (G1) foi tratado através da Artrocentese e o segundo (G2), tratado com a PRA. Todos os pacientes foram reexaminados após seis meses. Resultados: Com exceção do movimento protrusivo, houve diferenças significativas entre os dois grupos para as mudanças percentuais das medidas de AMM pela quantidade de abertura sem dor, abertura sem assistência, abertura máxima com assistência, movimentos laterais direitos e laterais esquerdos (p < 0,05). Conclusão: Dentro do contexto do estudo atual, a PRA, não invasiva e de menor custo, proporcionou melhores resultados na melhoria da AMM no gerenciamento de casos de DDAcR (AU)


Subject(s)
Humans , Male , Female , Temporomandibular Joint , Arthrocentesis , Intervertebral Disc Displacement
3.
Braz. dent. sci ; 24(4, suppl 1): 1-8, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1349287

ABSTRACT

Objective: was to evaluate the effect of four conservative treatment modalities on the pain level of patients with temporomandibular joint (TMJ) anterior disc displacement with reduction (ADDwR). Material and methods:100 subjects (64 females and 36 males) were selected, divided into four groups, 25 patients of each. Subjects of Group I have been treated with behavioral therapy. Subjects of Group II had been treated with Photobiomodulation therapy (PBMT). Subjects of Group III had been treated by anterior repositioning splint (ARS). Subjects of Group IV had been treated by a stabilization splint. The pain was evaluated by visual analog score (VAS) from 0 to 10. Statistical analysis was done using one-way ANOVA test for comparison between groups. Within each group, a comparison between baseline and after treatment was done using paired t-test (p<0.05). Results: There was a statistical difference between the pain scores of the different groups after treatment (p≤0.05). Also, there were statistical differences between all groups (p≤0.05) except that between group II and group III (p˃0.05). Conclusion: The use of stabilization splint and ARS are effective non-invasive methods for reducing the pain level in the treatment of TMJ ADDwR cases.(AU)


Objetivo: avaliar o efeito de quatro modalidades de tratamento conservador no nível de dor de pacientes com deslocamento anterior do disco articular com redução. Material e Métodos: foram selecionados 100 indivíduos(64 mulheres e 36 homens), divididos em quatro grupos, 25 pacientes cada. Os indivíduos do Grupo I foram tratados com terapia comportamental. Os indivíduos do Grupo II foram tratados com terapia de fotobiomodulação. Os indivíduos do Grupo III foram tratados com placa de reposicionamento anterior. Os indivíduos do Grupo IV foram tratados com uma placa de estabilização. A dor foi avaliada pelo escala visual analógica (EVA) de 0 a 10. A análise estatística foi feita usando o teste ANOVA de uma via para comparação entre os grupos. Dentro de cada grupo, uma comparação entre a linha de base e após o tratamento foi feita usando o teste t pareado (p <0,05). Resultados: Houve diferença estatística entre os escores de dor dos diferentes grupos após o tratamento (p ≤ 0,05). Além disso, houve diferenças estatísticas entre todos os grupos (p ≤0,05), exceto entre o grupo II e o grupo III (p˃0,05). Conclusão: O uso de placa de estabilização e reposicionadora anterior são métodos não invasivos eficazes para reduzir o nível de dor no tratamento de casos de deslocamento anterior de disco articular sem redução.(AU)


Subject(s)
Humans , Male , Female , Occlusal Splints , Temporomandibular Joint Disc , Low-Level Light Therapy
4.
Braz. dent. sci ; 23(3): 1-6, 2020. ilus, tab
Article in English | BBO, LILACS | ID: biblio-1104370

ABSTRACT

Objective: was to evaluate the retentive force, fatigue resistance and deformity of clasps made from two materials cobalt chromium and poly ether ether ketone (PEEK). Material and Methods: sixteen models were fabricated,each one having lower 1st molar. Models were divided into two groups according to materials,group I (GI) for cobalt chromium (Co-Cr) and group II (GII) for PEEK. Each testing models and its clasps were mounted inside universal testing machine, the retention was measured by applying withdrawal force to it by this machine at 5 mm/min. The Fatigue resistance is measured by the reduction in retention through repeated insertion and removal cycles using robota chewing simulator. Removal and insertion cycling of clasps was carried out for 360, 730, 1080, 1,440, 2,116 and 2,880 cycles (corresponding to 3, 6, 9, 12, 18 and 24 months of simulated clinical use of a RPD) to simulate the fatigue resistance test. Deformity was measured before and after each cycling using a digital micrometer. Statistical analysis was done by 2-way-ANOVA test to detect significance effects of each variable. Results: Retention and fatigue resistance, after 360, 730, 1080, 1,440, 2,116 and 2,880 cycles totally the difference between Co-Cr and PEEK groups was statistically non-significant (P = 0.0980> 0.05) where (Co-Cr > PEEK). Deformation results, regardless to evaluation time, Co-Cr group recorded statistically significant higher deformation mean value than PEEK group (P = 0.008 < 0.05).Regardless to material group, deformation mean value changed nonsignificantly by time (P = 0.2882> 0.05). Conclusion: PEEK clasps (1.0 mm in cross section diameter) engage 0.50 mm undercut provide sufficient retention nearly similar that of Co-Cr clasps.(AU)


Objetivo: o objetivo foi avaliar a força de retenção, a resistência à fadiga e a deformidade dos grampos fabricados com dois materiais diferentes: cromo-cobalto (Co-Cr) e poliéter-éter-étercetona (PEEK). Materiais e métodos: dezesseis modelos foram confeccionados, cada um com 1º molar inferior. Os modelos foram divididos em dois grupos de acordo com o material: grupo I Co-Cr e grupo II para PEEK. Cada modelo de teste universal e seus grampos foram montados em uma máquina de teste universal. A retenção foi medida aplicando força de retirada por esta máquina a 5 mm/min. A resistência à fadiga foi medida pela redução na retenção através de ciclos repetidos de inserção e remoção usando um simulador do ciclo de mastigação. O ciclo de remoção e inserção dos grampos foi realizado por 360, 730, 1080, 1.440, 2.116 e 2.880 ciclos (correspondendo a 3, 6, 9, 12, 18 e 24 meses de uso clínico simulado de um RPD) para simular o teste de resistência à fadiga. A deformidade foi medida antes e após cada ciclo, usando um micrômetro digital. A análise estatística foi realizada pelo teste ANOVA de 2 fatores para detectar os efeitos de significância de cada variável. Resultados: A retenção e a resistência à fadiga após 360, 730, 1080, 1.440, 2.116 e 2.880 ciclos entre os grupos Co-Cr e PEEK não mostrou diferença estatisticamente significativa (p = 0,0980> 0,05), onde (Co-Cr> PEEK). Para os resultados da deformação, independentemente do tempo de avaliação, o grupo Co-Cr registrou um valor médio de deformação maior, com diferença estatística significativa, quando comparado com o grupo PEEK (p= 0,008 < 0,05). Independentemente do grupo de material, o valor médio da deformação foi alterado de forma não significativa pelo tempo (p= 0,2882> 0,05). Conclusão: os grampos PEEK (1,0 mm de diâmetro da seção transversal) engatam 0,50 mm retenção quase semelhante à dos grampos Co-Cr (AU)


Subject(s)
Resins, Synthetic , Chromium Alloys , Denture, Partial
SELECTION OF CITATIONS
SEARCH DETAIL